SPECIAL TOOLS Ratchet, 1/4" Sq Dr, HV Insulated (1057602-00-A) Ext Bar, Wobble, 1/4" Dr, HV Insulated (1057603-00-A) Skt, 1/4" Sq Dr, 13mm, HV Insulated (1057606-00-A) Magnet, Flexible, HV Insulated, 18" (1057607-00-A) Asy, Service Cover, Penthouse, Model 3 (1127845-00-A) Dummy Disconnect, Pyro, Safety (1131071-00-A) Kit, HV Pyro-disconnect Replacement, BRP (1133602-00-A ) Cap, Logic Conn, Inv, 3DU (1108272-00-B) Resistance meter, microohm, Hioki RM 3548 (1076927-00-A) Warning: Remove all jewelry (watches, bracelets, rings, necklaces,
earrings, ID tags, piercings, etc.) from your person, and all objects (keys,
coins, pens, pencils, tools, fasteners, etc.) from your pockets before
performing any procedure that exposes you to high voltage. Warning: If corrective eyewear is necessary to safely perform any
procedure, make sure that the eyewear is securely restrained to the head and
cannot fall off. Only technicians who have been trained in High Voltage Awareness are
permitted to perform this procedure. Proper personal protective equipment (PPE)
and insulating HV gloves with a minimum rating of class 0 (1000V) must be worn
at all times a high voltage cable, busbar, or fitting is handled. Refer to Tech
Note TN-15-92-003, "High Voltage Awareness Care Points" for additional safety
information. Remove Warning: HV insulating gloves and leather glove protectors must be
worn throughout the remainder of this procedure. Do not remove gloves or
protectors until otherwise noted.
Install
Note: The maximum acceptable resistance is 0.060 mΩ (60 μΩ). If the
resistance is above this value, escalate a Toolbox session, as appropriate.
Note: The maximum acceptable resistance is 0.045 mΩ (45 μΩ). If the
resistance is above this value, escalate a Toolbox session, as appropriate.
Pyrotechnic Battery Disconnect- Remove
1st Generation
2nd Generation
Pyrotechnic Battery Disconnect- Install
Torque 9 Nm
Generic Measurement - Actual busbars and fasteners might appear
different
1st Generation
2nd Generation