Tesla Model 3 Owners & Service Manuals

Tesla Model 3: Procedure (Three-Phase) (Except China)

  1. Open the charge port door.
  2. Disconnect 12V power. See 12V Power (Disconnect and Connect).
  3. Set the insulation multimeter to measure the DC voltage across the 12V auxiliary battery terminals.

Caution: If the voltage across the 12V auxiliary battery terminals is less than 10 volts or greater than 14 volts, the multimeter is not measuring reliably and must not be used. Use only a fully functional multimeter.

  1. Remove all loose articles and jewelry from your person.
  2. Put on safety glasses, High Voltage (HV) insulating gloves, and leather glove protectors.
  3. Prepare the insulation multimeter with slim test probes and alligator clips.

  Procedure (Three-Phase) (Except China)

  1. Attach the black negative alligator clip to the LH rear door striker.
  2. Set the insulation multimeter to DC voltage.

  Procedure (Three-Phase) (Except China) Procedure (Three-Phase) (Except China)

  1. Touch the red positive slim test probe to each of the lower 4 pin terminals of the charge connector highlighted in this illustration, and read the voltage:
  • If a terminal voltage is less than 10V, measure the next terminal, until all are measured.
  • If a terminal voltage is 10V or greater, stop this procedure and contact Service Engineering.
Note: Touch the sides of the terminals inside of the pin terminals, not the tips.

Procedure (Three-Phase) (Except China)

  1. Touch the red positive slim test probe to each of the terminals of the DC connector highlighted in this illustration, and read the voltage:
  • If a terminal voltage is less than 10V, measure the other terminal.
  • If a terminal voltage is 10V or greater, stop this procedure and contact Service Engineering.
Note: Touch the sides of the terminals inside of the pin terminals, not the tips.
  1. If all previous voltage readings were less than 10V, return to the procedure that specified the charge port voltage check.

    READ NEXT:

     Procedure (Three - Phase) (China)

    Open the charge port door. Disconnect 12V power. See 12V Power (Disconnect and Connect). Set the insulation multimeter to measure the DC voltage across the 12

     Deadfronts - Pin - Charge Port (NA) (Remove and Replace)

    SPECIAL TOOLS Cap, Logic Conn, Inv, 3DU (1108272-00-B) Test Pro

     Door and Hinge Cover - Charge Port (Remove and Replace)

      Remove Open the charge port door. Remove the 2nd row lower seat cushion. See Seat Cushion - Lower - 2nd Row (Remove and Repl

    SEE MORE:

     Platter Enclosure Air Leak Test

    DRAFT Warning: This procedure was derived from pre-production computer models, and might not reflect the real-world situation. Warnings and cautions might be missing. Follow safety requirements and use extreme caution when working on or near high voltage systems and components. SPECIAL TOOLS Pac

     About this Owner Information

    Document Applicability Owner information is updated regularly to reflect updates to your vehicle. However, in some cases, recently released features may not be described. To display information about recently released features, view the Release Notes on the touchscreen. Release Notes are disp

    © 2019-2024 Copyright www.tmodel3.com